edge
edge Logo

The World’s Most Innovative pH, EC and DO Meter

edge® meters are thin and lightweight, measuring just 12 mm (1⁄2”) thick and weighing less than 250 g (9 ounces). Each meter has an incredibly wide viewing angle, 14 cm (5.5”) LCD and a sensitive capacitive touch keypad.

edge Dedicated USB Ports
3parameters—pH,
EC and DO
0footprint
0.5inch thick
(12.7 mm)
8.8oz. weight
(250 g)
8hours battery life
5.5inch display
(14 cm)
2USB ports
edge Picture

A hybrid meter that can be used in portable, wall-mount and benchtop configurations

The versatile design of edge enables it to be used as a portable, wall-mount or benchtop meter. edge simplifies measurement, configuration, calibration, diagnostics, and logging and transferring data directly to a computer or USB drive.

Digital Smart Electrodes

edge measures pH, conductivity, and dissolved oxygen through its unique digital electrodes. These electrodes are auto-recognized and feature a built-in microchip that stores sensor type, ID, and calibration information that is automatically retrieved by edge once the electrode is connected.

edge Electrodes

Digital Smart Electrodes

edge measures pH, conductivity, and dissolved oxygen through its unique digital electrodes. These electrodes are auto-recognized and feature a built-in microchip that stores sensor type, ID, and calibration information that is automatically retrieved by edge once the electrode is connected.

edge blu USB Ports

Two USB Ports

edge includes a standard USB for exporting data with a flash drive and a micro USB port to connect to a computer for file export and for charging your edge when the cradle is not available.

Sleek, Portable Design

Due to its light weight, large screen and thin design, edge can be easily slipped into a backpack or messenger bag. edge offers up to 8 hours of battery life when used as a portable device.

edge blu Sleek, Porable Design

Sleek, Portable Design

Due to its light weight, large screen and thin design, edge can be easily slipped into a backpack or messenger bag. edge offers up to 8 hours of battery life when used as a portable device.

edge blu Data Logging

Data Logging

Store up to 1000 log records of data. Data sets include readings, GLP data, date and time. edge offers manual log-on-demand, manual log-on-stability, and interval logging.

Wall Mount Cradle and Electrode Holder with Built-in Cradle Included

The included wall mount cradle makes it easy to conserve space on the benchtop and can charge edge with the AC adapter. Ideal for continuous monitoring applications.

The included electrode holder features an adjustable swivel arm with a built-in cradle to hold edge securely in place at the optimum viewing angle.

Rechargeable Battery

The benchtop or wall-mount cradle can be used to recharge the meter battery. The battery can also be recharged through the micro USB port with either a computer connection or the power supply.

edge blu Product

Wall Mount Cradle and Electrode Holder with Built-in Cradle Included

The included wall mount cradle makes it easy to conserve space on the benchtop and can charge edge with the AC adapter. Ideal for continuous monitoring applications.

The included electrode holder features an adjustable swivel arm with a built-in cradle to hold edge securely in place at the optimum viewing angle.

Rechargeable Battery

The benchtop or wall-mount cradle can be used to recharge the meter battery. The battery can also be recharged through the micro USB port with either a computer connection or the power supply.

edge Technical Features

Basic Mode

Basic Mode

edge Basic Mode is ideal for routine measurements with a simplified screen and features.

CAL Check

CAL Check

edge features Hanna’s exclusive CAL Check to warn you if the bulb of the electrode is not clean or if the buffers are contaminated during calibration.

Sensor Check (using HI12301 and HI11311 only)

Sensor Check (using HI12301 and HI11311 only)

When using with Hanna’s electrodes, equipped with a matching pin, edge constantly checks the impedance of the pH measuring electrode to notify you in real time in the event of glass breakage. During calibration, Sensor Check verifies the state of the junction. The reference junction is also evaluated and reported on the display.

edge GLP

GLP

edge Digital Smart Electrodes feature a built-in microchip to store data of the last calibration performed: electrode’s offset, slope, date, time and buffer/standards. When any sensor (pH, EC, or DO) is connected to the edge, GLP data is automatically transferred.

edge Design Features

edge Capacitive touch buttons

Capacitive Touch Buttons

edge features a capacitive touch keypad for a distinctive, modern look. Since the keypad is part of the screen, the buttons don't get clogged with sample residue. The up and down keys move faster when continuously held (ideal for scrolling through numerous logs).

edge Easy to read LCD

Easy to read LCD

edge features a 5.5” (14 cm) LCD display that you can clearly view from over 5 m (16.4’). The large display, with its wide 150° viewing angle, provides one of the easiest to read LCDs in the industry.

edge 3.5 mm Probe Input

3.5 mm Probe Input

Plugging an electrode in has never been easier, no alignments, no broken pins, just connect the 3.5 mm plug and get started.

edge Clear, full text readout

Clear, full text readout

edge features clear, full text guides displayed on the bottom of the screen. There is no need to decipher scrambled abbreviations or symbols; these helpful messages guide you through every process quickly and easily.

Model Specific Features

Steady green

edge pH specification overview

Range
-2.00 to 16.00 pH;
-2.000 to 16.000 pH
Resolution
0.01 pH; 0.001 pH
Accuracy
(@25°C/77°F)
±0.01 pH; ±0.002 pH
Calibration
Basic mode: Automatic, up to 3 points calibration 5 standard buffer Standard mode: Automatic up to 5 points calibration 7 standard buffers (1.68, 4.01 or 3.00, 6.86, 7.01, 9.18, 10.01, 12.45 ) and 2 custom buffers

edge pH parameter features

  • Resolution selectable from 0.01 and 0.001 pH
  • Range -2.000 to 16.000 pH
  • Accuracy ±0.002 pH for 0.001 pH resolution; ±0.01 for 0.01 resolution
  • Temperature readout (°C or °F)
  • Automatic Temperature Compensation (ATC)
  • CAL Check™ Indicators:
    • Probe condition
    • Response time
    • Check buffer
    • Clean electrode
  • Sensor Check™ Indicators:
    • Broken electrode
    • Clogged junction
  • GLP data
    • Records date, time, offset, slope and buffers used during calibration
  • Five-point calibration
    • A choice of seven pre-programmed buffers plus two selectable custom buffers
  • Calibration tag on screen
    • Identifies buffers used for current calibration
  • Calibration expiration warning
Flashing yellow

edge EC specification overview

Range
0.00 to 29.99 μS/cm; 30.0 to 299.9 μS/cm; 300 to 2999 μS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm absolute EC
Resolution
0.01 μS/cm; 0.1 μS/cm; 1 μS/cm; 0.01 mS/cm; 0.1 mS/cm
Accuracy
(@25°C/77°F)
±1% of reading (±0.5 μS or 1 digit, whichever is greater)
Calibration
single cell factor calibration; six standards available: 84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/ cm, 80.0 mS/cm, 118.8 mS/cm, one point offset: 0.00 μS/cm

edge EC parameter features

  • Digital four-ring conductivity probe
    • Covers all ranges from 0.00 μS/cm to 500 mS/cm (absolute EC)
  • Accuracy
    • ± 1% of the reading (±0.05 μS/cm or 1 digit, whichever is greater)
  • Calibration
    • Offset (0 μS/cm) and cell factor calibration
    • Choice of 5 standards (auto-recognition)
  • Auto-ranging or manual range selection
  • EC, TDS and salinity reading modes
  • Temperature compensation
    • Automatic
    • NoTC (absolute)
  • GLP data
    • Records date, time, offset and cell factor
    • Data of the last performed calibration is stored in the probe: date, time, cell constant, temperature coefficient, reference temperature and battery status. When the probe is connected to edge EC , GLP data is automatically transferred
  • Adjustable EC to TDS conversion factor
  • Adjustable temperature correction Coefficient
  • Seawater salinity units
    • %NaCl
    • PSU
    • g/L
Steady Red

edge DO specification overview

Range
0.00 to 45.00 ppm (mg/L);
0.0 to 300.0% saturation
Resolution
0.01 ppm (mg/L); 0.1% saturation
Accuracy
(@25°C/77°F)
±1.5% of reading ±1 digit
Calibration
one or two-point at 0% (HI7040 solution) and 100% (in air)

edge DO parameter Features

  • Clark type digital polarographic probe with easy-to-replace membrane cap
    • Covers all ranges from 0.00 to 45.00 mg/L (ppm); 0.0 to 300% saturation
  • Accuracy ±1.5% full scale
  • One or two-point calibration (HI7040), 0% (solution) and 100% (air)
  • Automatic Temperature Compensation from 0 to 50 °C
  • GLP data
    • Records date, time, calibration standards, altitude value and salinity value
  • Altitude compensation from -500 to 4000 meters (-1640 to 13,123’)
  • Salinity compensation from 0 to 40g/L